ATEX Certified Air-Powered Industrial Vacuum Cleaners for Flammable Liquids - FL Series

phone

Contact us now.

973-759-4600

Categories

ATEX Certified Air-Powered Industrial Vacuum Cleaners for Combustible Dusts - CD Series ATEX Certified Air-Powered Industrial Vacuum Cleaners for Flammable Liquids - FL Series ATEX Certified Air-Powered Industrial Vacuum Cleaners, Submerged Recovery - SR Series Explosion-Proof Industrial Vacuum Cleaners - Electric Operation Industrial Vacuums for Silica Dust with HEPA Filtration VAC-U-MAX Track Vacuum, designed for cleaning Mass Transit train and subway tracks. General Purpose Industrial Vacuums » Dry Only Vacuums: Portable Industrial Vacuums » Wet/Dry Vacuums: Portable Industrial Vacuums » Wet/Dry Vacuums: Portable Industrial Vacuums Air Operated Industrial Vacuum Cleaners VAC-U-MAX Industrial Vacuums, HEPA Vacuums Industrial Vacuum Cleaners for Fine Powders Continuous Duty Vacuums VAC-U-MAX Industrial Vacuums: Combustible Dust Vacuums Central Vacuum Systems » Custom Engineered Central Vacuum Cleaning Systems » Pre-Engineered Systems for 1-3 Operators Liquid Recovery Vacuums Flammable Liquid Recovery Metalworking Shop Vacuums & Central Systems » Steel Shot & Grit Systems Pharmaceutical Vacuums Trim Recovery Vacuums Intercept Hoppers and Pre-Separators Accessories » Hose » Toolkits » Cartridge Filter Cleaning Tool » Intercept Cover » Dollies » Drums » Filters » Mufflers » Gaskets » Miscellaneous Accessories » Repair Kits

Product Lines

VAC-U-MAX Pneumatic Conveying Systems Batch Weighing Systems Bulk Bag Unloader Bulk Bag Loader Bag Dump Stations Bag Compactors Flexible Screw Conveyors Aero-Mechanical Conveyors Industrial Vacuum Cleaners Central Vacuum Systems
ATEX Certified Air-Powered Industrial Vacuum Cleaners for Combustible Dusts - CD Series ATEX Certified Air-Powered Industrial Vacuum Cleaners for Flammable Liquids - FL Series ATEX Certified Air-Powered Industrial Vacuum Cleaners, Submerged Recovery - SR Series Explosion-Proof Industrial Vacuum Cleaners - Electric Operation Industrial Vacuums for Silica Dust with HEPA Filtration VAC-U-MAX Track Vacuum, designed for cleaning Mass Transit train and subway tracks. General Purpose Industrial Vacuums » Dry Only Vacuums: Portable Industrial Vacuums » Wet/Dry Vacuums: Portable Industrial Vacuums » Wet/Dry Vacuums: Portable Industrial Vacuums Air Operated Industrial Vacuum Cleaners VAC-U-MAX Industrial Vacuums, HEPA Vacuums Industrial Vacuum Cleaners for Fine Powders Continuous Duty Vacuums VAC-U-MAX Industrial Vacuums: Combustible Dust Vacuums Central Vacuum Systems » Custom Engineered Central Vacuum Cleaning Systems » Pre-Engineered Systems for 1-3 Operators Liquid Recovery Vacuums Flammable Liquid Recovery Metalworking Shop Vacuums & Central Systems » Steel Shot & Grit Systems Pharmaceutical Vacuums Trim Recovery Vacuums Intercept Hoppers and Pre-Separators Accessories » Hose » Toolkits » Cartridge Filter Cleaning Tool » Intercept Cover » Dollies » Drums » Filters » Mufflers » Gaskets » Miscellaneous Accessories » Repair Kits

Product Lines

Products by Application Batch Weighing Systems Bulk Bag Unloader Bulk Bag Loader Bag Dump Stations Bag Compactors Flexible Screw Conveyors Aero-Mechanical Conveyors Industrial Vacuum Cleaners Central Vacuum Systems
Request For Quote »

ATEX Certified Air-Powered Industrial Vacuum Cleaners for Flammable Liquids - FL Series

ATEX Certified Air-Operated Industriual Vacuums Cleaners for Flammable Liquid cleanup. The VAC-U-MAX FR Series are Flammable Liquid Vacuums designed for safe reovery of gasoline, diesel fuel, JP-4, JP-5 and JP-8 jet fuels, solid materials and non-combustible liquids. 

VAC-U-MAX Industrial Vacuum Cleaners meet NFPA 77 requirements for grounding and bonding - meeting the definition of an “intrinsically-safe system”.

"Intrinsically-safe" systems are designed to be unable to release thermal or electrical energy which can cause ignition of flammable materials (liquids or combustible dusts). Explosion sources include electrical sparks and arcs, flames, hot surfaces, static, electromagnetic radiation, and chemical reactions. Intrinsic safety is covered under OSHA Regulations (Standards - 29 CFR), hazardous (classified) locations 1910.307 and 1926.407. VAC-U-MAX Combustible Dust Air-Vacs are all "Intrinsically Safe", that being they are air-powered, do not use electricity, and do not generate any heat from operation. 

What is ATEX? ATEX or “Atmosphères Explosibles” is a Nationally Recognized Testing Laboratory (NRTL) providing a set of directives and standards as set by the EU for controlling explosive atmospheres with the goal of improving the health, safety and protection of workers. 

These VAC-U-MAX Industrial air operated vacuums are a “system” and include the vacuum cover, drum, dolly, vacuum hose and cleaning tools, compressed air hose with quick-disconnect fittings, and polybag drum liners. There are no components that are supplied by the customer and we are therefore able to offer a suitable-for-service certification in a Class II, Division 2 environment.   

23954/02

MDL55, Twin Venturi Vacuum for Flammable Liquids - Carbon Steel

Item #: 23954/02

Includes twin venturi power unit, 55 gallon collection container and flammable liquids tool kit...
23954

MDL55, Single Venturi, Vacuum for Flammable Liquids - Carbon Steel

Item #: 23954

Single venturi power unit, 55 gallon collection container, cover unit fits any minimum 16 gauge...